Wyślij wiadomość
RM 1902, EASEY BLDG., 253-261 HENNESSY ROAD, WANCHAI, HONGKONG
Dom ProduktyPompy hydrauliczne Parker Denison

Denison T6DR-024-1R00-C40-A1 T6DR-028-1R00-B20-A1 T6DR-031-1L00-B20-A1 T6DR-035-3L00-B30-A1

Denison T6DR-024-1R00-C40-A1 T6DR-028-1R00-B20-A1 T6DR-031-1L00-B20-A1 T6DR-035-3L00-B30-A1

  • Denison T6DR-024-1R00-C40-A1 T6DR-028-1R00-B20-A1 T6DR-031-1L00-B20-A1 T6DR-035-3L00-B30-A1
Denison T6DR-024-1R00-C40-A1 T6DR-028-1R00-B20-A1 T6DR-031-1L00-B20-A1 T6DR-035-3L00-B30-A1
Szczegóły Produktu:
Miejsce pochodzenia: FRANCJA
Nazwa handlowa: Parker/Denison
Numer modelu: T6DR-035-3R00-B32-A1 T6DR-038-1R03-C40-A1 T6DR-042-2R01-C42-A1 T6DR-045-3R00-B20-A1
Zapłata:
Minimalne zamówienie: 1
Cena: On request
Szczegóły pakowania: Karton, drewniane pudełko
Czas dostawy: 7-10 dni
Zasady płatności: T/T, Western Union
Możliwość Supply: 100
Kontakt
Szczegółowy opis produktu
Model NR: T6DR-050-3R00-C42-A1 Kod: 024–50540–0 / 002
High Light:

variable volume pump

,

parker axial piston pump

Pompy hydrauliczne Mobilne i przemysłowe T6 * R Technologia łopatkowa Denison, o stałej wydajności

WIĘKSZY PRZEPŁYW
Większy przepływ dla rozmiaru obwiedni uzyskuje się dzięki pierścieniom krzywkowym o zwiększonym przemieszczeniu: przy dużych dopuszczalnych prędkościach z wlotem atmosferycznym
C → 3 do 31 GPM, 10 do 100 ml / obr.
D → 14 do 50 GPM, 48 do 158 ml / obr.
E → 42 do 72 GPM, 132 do 227 ml / obr.

WYŻSZE CIŚNIENIE
Ciśnienie znamionowe do 275 barów, co pozwala zmniejszyć rozmiar i koszt siłowników, zaworów i przewodów.

LEPSZA WYDAJNOŚĆ
Większa wydajność pod obciążeniem, co zwiększa wydajność i zmniejsza koszty ogrzewania i eksploatacji.

ELASTYCZNOŚĆ MONTAŻU
Pojedyncze pompy: 4 pozycje + 4 na tylnym napędzie.
Potrójne pompy: 128 pozycji + 2 na tylnym napędzie.

TYLNY NAPĘD
Podkładki montażowe i złącza są w pełni zgodne z SAE J744c i ISO 3019-1.
Pojedyncze pompy SAE A / B / C tylne adaptery.
Złącza SAE A / B / BB / C
Pompy potrójne SAE Adapter i złącze.

NIŻSZE POZIOMY HAŁASU
Zwiększ bezpieczeństwo i akceptację operatora.

KOMPLETNA ZGODNOŚĆ
Zgodnie z normami SAE - J744c dla 2 śrub i ISO 3019-1 w różnych oferowanych opcjach wałów z wpustem i klinem.

OGÓLNE INSTRUKCJE APLIKACJI
1. Sprawdź zakres prędkości, ciśnienie, temperaturę, jakość płynu, lepkość i obroty pompy.
2. Sprawdź warunki wlotowe pompy, jeśli może ona spełnić wymagania aplikacji.
3. Rodzaj wału: sprawdź, czy może on utrzymywać moment obrotowy systemu.
4. Sprzęgło należy wybrać, aby zminimalizować obciążenie wału pompy (ciężar, niewspółosiowość).
5. Filtracja: musi być odpowiednia dla najniższego poziomu zanieczyszczenia.
6. Środowisko pompy: w celu uniknięcia odbicia hałasu, zanieczyszczenia i wstrząsów.

Firma SAAR specjalizuje się w pompach, silnikach, zaworach, łożyskach, sprzęgłach, skrzyni biegów, częściach zamiennych do silników, elementach filtrujących, złączkach, złączach, komponentach elektronicznych i akcesoriach, części zamiennych do urządzeń mobilnych.

Pompy hydrauliczne Parker Denison Mobilne i przemysłowe Pompy T6DR w sprzedaży, krótki czas realizacji, najlepsza cena !!!

024–44611–0 T6DR-020-1R00-B30-A1
024–33846–0 T6DR-020-3L00-C42-A1
024–49454–0 T6DR-024-1L00-B20-A1
024–45954–0 T6DR-024-1R00-B20-A1
024–40946–0 T6DR-024-1R00-C40-A1
024–44610–0 T6DR-024-3L00-B30-A1
024–49235–0 / 020 T6DR-024-3L02-B20-A1
024–31697–0 T6DR-024-3R00-B20-A1
024–33847–0 T6DR-024-3R00-B30-A1
024–31697–0 / 02 T6DR-024-3R02-B20-A1
024–50178–0 T6DR-028-1L00-B20-A1
024–31844–0 T6DR-028-1R00-B20-A1
024–31844–0 / 002 T6DR-028-1R00-B22-A1
024–40037–0 T6DR-028-1R00-B30-A1
024–31289–0 / 002 T6DR-028-1R00-C42-A1
024–31844–0 / 021 T6DR-028-1R02-B21-A1
024–31844–0 / 022 T6DR-028-1R02-B22-A1
024–33848–0 T6DR-028-2L00-B20-A1
024–31846–0 T6DR-028-3L00-A10-A1
024–31845–0 T6DR-028-3L00-B20-A1
024–31845–0 / 002 T6DR-028-3L00-B22-A1
024–31845–0 / 020 T6DR-028-3L02-B20-A1
024–31847–0 T6DR-028-3R00-B20-A1
024–31847–0 / 010 T6DR-028-3R01-B20-A1
024–31847–5 / 010 T6DR-028-3R01-B20A5
024–31847–0 / 012 T6DR-028-3R01-B22-A1
024–49199–0 / 020 T6DR-028-3R02-B30-A1
024–49199–0 / 021 T6DR-028-3R02-B31-A1
024–31520–0 T6DR-031-1L00-B20-A1
024–40890–0 T6DR-031-1L00-B30-A1
024–40599–0 T6DR-031-1R00-A10-A1
024–40599–0 / 001 T6DR-031-1R00-A11-A1
024–31192–0 T6DR-031-1R00-B20-A1
024–31458–0 / 002 T6DR-031-1R00-C42-A1
024–31192–0 / 03 T6DR-031-1R03-B20-A1
024–45338–0 / 010 T6DR-031-2R01-C40-A1
024–31848–0 T6DR-031-3L00-B20-A1
024–31848–4 T6DR-031-3L00-B20A4
024–33574–0 T6DR-031-3R00-A20-A1
024–33423–0 / 002 T6DR-031-3R00-C42-A1
024–31456–0 T6DR-035-1R00-A10-A1
024–40965–0 T6DR-035-1R00-A20-A1
024–31849–0 T6DR-035-1R00-B20-A1
024–31849–0 / 001 T6DR-035-1R00-B21-A1
024–31849–0 / 002 T6DR-035-1R00-B22-A1
024–49976–0 T6DR-035-1R00-B30-A1
024–49976–0 / 001 T6DR-035-1R00-B31-A1
024–40674–0 / 002 T6DR-035-1R00-C42-A1
024–50640–0 T6DR-035-2R00-A10-A1
024–40413–0 T6DR-035-2R00-C42-A1
024–31850–0 T6DR-035-3L00-B20-A1
024–31853–0 T6DR-035-3L00-B30-A1
024–31453–0 T6DR-035-3L00-C40-A1
024–31851–0 T6DR-035-3R00-B20-A1
024–31851–0 / 002 T6DR-035-3R00-B22-A1
024–31852–0 T6DR-035-3R00-B30-A1
024–31852–0 / 002 T6DR-035-3R00-B32-A1
024–31556–0 T6DR-035-3R00-C42-A1
024–31556–0 / 023 T6DR-035-3R02-C43-A1
024–31451–0 / 030 T6DR-038-1L03-B20-A1
024–33328–0 T6DR-038-1R00-B20-A1
024–31854–0 T6DR-038-1R00-B30-A1
024–45126–0 T6DR-038-1R00-C40-A1
024–31139–0 / 002 T6DR-038-1R00-C42-A1
024–31139–0 / 022 T6DR-038-1R02-C42-A1
024–45126–0 / 030 T6DR-038-1R03-C40-A1
024–31139–0 / 032 T6DR-038-1R03-C42-A1
024–33237–0 / 002 T6DR-038-2R00-C42-A1
024–33237–0 / 032 T6DR-038-2R03-C42-A1
024–33626–0 T6DR-038-3L00-B20-A1
024–49726–0 T6DR-038-3R00-A20-A1
024–26834–0 T6DR-038-3R00-B30-A1
024–31709–0 T6DR-038-3R00-C42-A1
024–49726–0 / 011 T6DR-038-3R01A21-A1
024–31193–0 / 030 T6DR-038-3R03-B20-A1
024–33240–0 T6DR-042-1R00-A10-A1
024–31457–0 T6DR-042-1R00-B20-A1
024–40111–0 / 002 T6DR-042-1R00-C42-A1
024–40111–0 / 023 T6DR-042-1R02-C43-A1
024–31457–0 / 030 T6DR-042-1R03-B20-A1
024–49275–0 T6DR-042-2L00-C40-A1
024–31461–0 / 002 T6DR-042-2R00-C42-A1
024–31461–0 / 012 T6DR-042-2R01-C42-A1
024–31461–0 / 032 T6DR-042-2R03-C42-A1
024–33239–0 T6DR-042-3L00-B20-A1
024–33239–0 / 030 T6DR-042-3L03-B20-A1
024–31460–0 T6DR-042-3R00-B20-A1
024–49251–0 / 021 T6DR-042-3R02-B31-A1
024–50718–0 T6DR-045-1L00-C43-A1
024–31855–0 T6DR-045-1R00-B20-A1
024–31138–0 T6DR-045-1R00-C40-A1
024–31138–0 / 002 T6DR-045-1R00-C42-A1
024–31855–0 / 03 T6DR-045-1R03-B20-A1
024–31452–0 T6DR-045-3L00-B20-A1
024–31044–0 T6DR-045-3L00-C42-A1
024–31452–0 / 020 T6DR-045-3L02-B20-A1
024–31452–0 / 030 T6DR-045-3L03-B20-A1
024–26825–0 T6DR-045-3R00-B20-A1
024–44965–0 / 002 T6DR-045-3R00-C42-A1
024–50540–0 T6DR-050-3R00-C40-A1
024–50540–0 / 002 T6DR-050-3R00-C42-A1
024–50540–0 / 003 T6DR-050-3R00-C43-A1
024–50364–0 / 010 T6DR - B24-3L01-B20-A1
024–31691–0 T6DR - B38-1R00-B20-A1
024–49145–0 T6DR - B42-3R00-C40-A1
024–44484–0 T6DR - B45-3L00-B30-A1

Saar HK Electronic Limited
Dodaj: Rm 1506,28 # Moyu Rd, Szanghaj, Chiny, 201805
Tel .: + 86–21–5956 1370
Faks: + 86-21-5012 3536
E-mail: jason@hydraulicpumpvalve.com
Skype: jason.saar
Komórka / WhatsApp: +8613918187448

Szczegóły kontaktu
Saar HK Electronic Limited

Osoba kontaktowa: Mr. Jason

Wyślij zapytanie bezpośrednio do nas (0 / 3000)

Inne produkty